Fan Cycler
The fan cycler function cycles the HVAC system fan for an ON period followed by an Off
period continuously. Used to provide minimum air ventilation requirements. When the Fan
ON time is set to a value greater than 0, an additional “Cycler” FAN mode is present when
pressing the FAN button.
Fan ON Time Range: 0-120 minutes Default: 0 (=OFF)
Fan OFF Time Range: 10-120 minutes Default: 10
Restore Defaults Range: Yes, No Default: No
Restores all settings to factory defaults.
Press Yes to restore defaults.
Press No to exit and not restore defaults.
Relay Status Display the status (on/off) of the thermostat output relays
BE SURE TO PAIR THE Z-WAVE RCS THERMOSTAT WITH THE ‘Z-
STICK S2’ Z-WAVE CONTROLLER.